Alternating Current: Class 12 CBSE Physics NCERT Notes
CBSEPhysicsAlternating Currents
These CBSE Class 12 Physics notes connect sinusoidal current and voltage to phasors, series LCR resonance, AC power and transformers. Use the clickable index to move between derivations, worked examples and the chapter summary.

Peak, mean and RMS: three different quantities
The notes begin with sinusoidal AC, whose successive half-cycles have opposite signs. The peak is the amplitude of the waveform, not its average or effective value. The signed mean over a complete cycle is zero because the charge transferred in one direction is balanced by charge transferred in the other. For a sinusoid, the positive half-cycle mean is times the peak; the negative half-cycle mean has the same magnitude with the opposite sign.
The root mean square (RMS) value answers a different question: what steady current would produce the same heat in the same resistor over the same time? Heating depends on current squared, so the two half-cycles contribute rather than cancel. For a sinusoid, the RMS value is the peak divided by . The examples on supply voltage and meter readings help you distinguish the amplitude in a time equation from an RMS rating.

Alternating Currents | Class 12 | NCERT Notes
In the StudentCurio app
These revision notes cover AC fundamentals, phasors, reactance and impedance, series LCR circuits and resonance, AC power, and generators and transformers. They help Class 12 students review key concepts and calculations in alternating current.
Use phasors to track which quantity leads
A phasor represents a sinusoid in steady state, after transients have died away. In the notes’ sine convention, its vertical projection gives the instantaneous value, while the angle between two same-frequency phasors gives their phase difference. For a pure resistor, voltage and current are in phase. In an ideal inductor, current lags voltage by a quarter-cycle. In an ideal capacitor, current leads voltage by a quarter-cycle.
The derivations explain why the two reactive elements behave differently. The inductor’s voltage depends on the rate of change of current, whereas the capacitor’s current depends on the rate of change of voltage. Inductive reactance rises with frequency; capacitive reactance falls as positive frequency increases. Both are measured in ohms, but neither represents resistive heating in the ideal element.

Common mistake: adding all three voltage magnitudes
The same current flows through each element in a series LCR circuit, labelled RLC in the notes. Taking that current as the reference puts the resistor voltage along the reference direction. The inductor voltage is a quarter-cycle ahead and the capacitor voltage is a quarter-cycle behind. Those two voltages therefore point in opposite directions on the phasor diagram: subtract their magnitudes before combining the result at right angles with the resistor voltage.
The resulting impedance is . Squaring the difference gives the correct magnitude, but keep track of its sign separately. A positive difference means the source voltage leads the current; a negative difference means it lags. With the impedance known, divide peak voltage by it for peak current, or RMS voltage by it for RMS current. Mixing the two conventions gives the wrong current.
When a frequency sweep produces resonance
At series resonance, inductive and capacitive reactances are equal. The two reactive voltages cancel in the source-voltage sum, but the individual voltages need not be zero. The resonant frequency is . At that frequency, impedance equals the series resistance and the source voltage and current are in phase. The current is largest when the source amplitude is held fixed and the series resistance is nonzero.
The notes use the frequencies on either side of resonance where average power falls to half its resonant value to define bandwidth. The current amplitude there is not half its maximum: it is the maximum divided by , because resistive power depends on current squared. For fixed inductance and capacitance, lower series resistance gives a narrower bandwidth and a higher quality factor.
Why current can flow without average power
The average-power derivation starts with instantaneous power, the product of voltage and current at the same moment. Averaging over a full cycle gives , where is the phase difference. The RMS product alone is apparent power. The power factor tells you what fraction of that product is average power; for the series circuits in the notes it is .
In a pure resistor, the power factor is one. In a pure ideal inductor or capacitor, it is zero even when current flows. The element stores energy during part of the cycle and returns it during another. This is what wattless current means: the net energy transferred over a full cycle is zero, not that instantaneous power is always zero.

Chokes and transformers: two uses of induction
A choke coil limits alternating current through inductive reactance. Its winding resistance is kept low to limit heating. A transformer, by contrast, changes alternating voltage through mutual induction between two windings. In the ideal model, the secondary-to-primary voltage ratio follows the turns ratio, and the current ratio under load is reciprocal. A step-up transformer therefore increases voltage without increasing frequency or creating power.
The notes distinguish this ideal model from a real transformer, where flux leakage, winding resistance, eddy currents and hysteresis affect performance. Laminating the core reduces eddy currents. When an example specifies efficiency, use it to relate useful output power to input power rather than treating the two as equal. The overview mentions generators, but the supplied device pages cover chokes and transformers, not generator operation.
Use the index to check your reasoning
The clickable index separates topic notes from worked examples, so you can go directly to a derivation when a calculation step is unclear. Before reading the example on varying source frequency, predict how each reactance changes and what that implies for the phase difference across resonance. When reviewing the transformer examples, identify whether the unknown is a voltage, a current or a power before choosing a ratio.
Use the chapter summary as a final check on conditions, not just formulas. Can you explain why the RMS conversion given here is specific to a sinusoid, why the source amplitude matters when identifying the maximum resonant current, and why an ideal transformer’s power balance cannot replace an efficiency calculation?
Spotted an error? Report a correction. Practise this in the app: notes, formula sheets and mind maps.













































































































































































Loading comments…