Skip to content

Current Electricity: Class 12 NCERT Physics Textbook Guide

CBSEPhysicsCurrent Electricity

This NCERT textbook chapter for CBSE Class 12 Physics connects electric current in a circuit to the motion of charge carriers inside a metal. Use this guide to read the chapter’s derivations and graphs with attention to what each equation measures and when it applies.

A cut-away metal wire shows fixed ions and electrons moving in zigzag paths, with a net drift opposite the electric field while the conventional current points along the field through the cross-section.
Electrons drift against the field, so conventional current flows along it.

Electric current measures net charge flow

The chapter opens by contrasting the changing current in lightning with the steadier current in devices such as a torch or a cell-driven clock. To define current, choose a forward direction through a cross-section and count the net charge that crosses it. The sign matters: negative charge moving forward contributes to current in the opposite sense from positive charge moving forward. A negative result means the conventional current points opposite to the direction you chose.

For steady current, the net charge crossing the section is proportional to the elapsed time, so I=q/tI=q/t. For a changing current, the same ratio over a finite interval gives an average. The instantaneous current is the limit of ΔQ/Δt\Delta Q/\Delta t as the interval tends to zero. Current is measured in amperes.

Preview of Current Electricity | Class 12 | NCERT Textbook

Current Electricity | Class 12 | NCERT Textbook

In the StudentCurio app

This textbook chapter covers current and drift, Ohm’s law, resistance and resistivity, electrical power, cells, and circuit analysis using Kirchhoff’s laws and bridge circuits. It helps Class 12 students build conceptual understanding and practise current-electricity problems.

Electron drift: motion without a net flow

In the chapter’s model of metallic conduction, mobile electrons move through a background of fixed positive ions. With no electric field, the electrons are already moving, but their random velocities average to zero. The absence of current therefore means there is no net motion of charge, not that the electrons are stationary.

An applied field accelerates electrons between collisions. Because their charge is negative, their average drift is opposite to the field, while conventional current is along the field. The model uses a relaxation time τ\tau to describe the average effect of collisions, not a fixed interval that every electron follows. This distinction is what lets the textbook describe a steady average drift even though individual electrons accelerate between collisions.

From drift speed to current density

The textbook links the microscopic model to a measurable current through I=neA∣vd∣I=neA|\mathbf{v}_d|. Here nn is the number of free electrons per unit volume, ee is the magnitude of the electron charge, and AA is the cross-sectional area normal to the flow. In the uniform metallic conductor considered here, current density has magnitude j=I/Aj=I/A and is measured in amperes per square metre. Dividing by area makes it possible to compare the flow per unit area in conductors of different sizes.

Mobility describes a different quantity: the drift speed per unit electric field. It is positive and is measured in square metres per volt-second. In the chapter’s electron model, μ=eτ/m\mu=e\tau/m, where mm is the electron mass. Keeping mobility separate from current density helps distinguish the response of the carriers from the charge flow they collectively produce.

When Ohm’s law and the slab formula apply

Ohm’s law states that the potential difference across a conductor is proportional to the current through it when the resistance is constant under the conditions considered. Writing V=IRV=IR as a law therefore says more than calculating the ratio V/IV/I at one point. The drift derivation also has a condition: it treats the free-electron number density and relaxation time as independent of the electric field.

Use the textbook’s slab diagram to separate resistance from resistivity. For a uniform conductor of length ll and constant cross-sectional area AA, R=ρl/AR=\rho l/A. With resistivity and area unchanged, doubling the length doubles the resistance. With resistivity and length unchanged, halving the area doubles it. Resistance is measured in ohms; resistivity is measured in ohm-metres and does not depend on the specimen’s dimensions.

What the voltage–current graphs can tell you

The chapter’s characteristic curves show several distinct ways in which a device can fail to obey Ohm’s law. The voltage and current may cease to be proportional. Reversing the voltage may also fail to produce an equal and opposite current, as in the diode example. In the gallium arsenide example, more than one voltage can correspond to the same current. These are different observations: a departure from proportionality does not by itself tell you what happens when the voltage reverses.

Before interpreting a graph, identify which quantity is on each axis and check the scales. The diode figure uses different scales for positive and negative values, so the apparent sizes of the two branches are not a reliable comparison on their own.

Good to remember: resistivity changes with temperature

For a metal near a reference temperature T0T_0, the chapter gives the approximation ρ(T)=ρ0[1+α(T−T0)]\rho(T)=\rho_0[1+\alpha(T-T_0)], where ρ0\rho_0 is the resistivity at that reference temperature. The coefficient α\alpha is positive for the metals described by this approximation. The formula is useful only over a range in which the graph is nearly straight; the copper curve shows why it should not be extrapolated far from that range.

The textbook contrasts copper with alloys such as nichrome, manganin and constantan, whose resistivities vary relatively little with temperature. That weak dependence makes them useful for standard resistors. A typical semiconductor shows a different trend: its resistivity decreases as temperature rises.

How to use the textbook examples and diagrams

Read the copper-wire example after tracing the derivation from drift speed to current. Before reading the calculation, identify which given quantities describe the wire and which assumption connects the number of copper atoms to the number of conduction electrons. Then use the schematic of repeated collisions to distinguish an individual electron’s path from the average motion represented by drift velocity.

The chapter also covers electrical power, cells, Kirchhoff’s laws and bridge circuits. As you move from the conductor model to circuit analysis, keep track of what each quantity describes: a field or flow inside a material, a potential difference across a component, or a current through a branch. That distinction helps you decide which relations belong in a circuit equation.

Spotted an error? Report a correction. Practise this in the app: notes, formula sheets and mind maps.

Discussion

Sign in to join the discussion

Loading comments…

More for Current Electricity

More for Electric Charges and Fields

More for Electrostatics

More for Electrostatic Potential and Capacitance

More for Capacitance

More for Moving Charges and Magnetism

More for Magnetic Effects of Current

More for Magnetism and Matter

More for Magnetic Properties of Matter

More for Electromagnetic Induction

More for Alternating Currents

More for Electromagnetic Waves

More for Ray Optics

More for Wave Optics

More for Dual Nature of Matter and Radiation

More for Atomic Physics

More for Nuclear Physics

More for Semiconductor Electronics

More for Electronic Devices

More for Physics

More for Semiconductors